 Solar Power System

 

Solar Power System Off-grid 24 Vdc Solar Power System with 5-day Reserve Power

Series: SPSB-24VDC

Features

     5-day Minimum System Reserve Power

     Provides Regulated 24 Vdc Output

     Weatherproof Fiberglass Enclosure

     Preassembled, Prewired, Ready-To-Install

     Deep-cycle Maintenance Free Battery

    
Applications

  • Wireless Sensors
  • Radio Transmitters, Receivers
  • Process Controls, Instrumentation
  • LED Lighting
  • Oil & Gas Instrumentation
  • SCADA & Telemetry
  • Pond Aeration Systems
  • Security Systems
  • Surveillance Equipment
  • Irrigation System
  • Pool & Spa Controls
  • Water Pumping, Valves
Description

Models include a weatherproof, fiberglass/plastic blend enclosure with a gasketed hinged door. Each model includes all the required system components to get you up and running right out of the box. Just mount and connect the included solar panel, Install and connect your equipment, flip the internal circuit breaker and you done.

How to Select the Correct Solar Power System for Your Application

Solar Zone Map 1. Identify the zone your system will be installed from the map on the right.

2. Use the formula below to determine the amp hours per day your equipment requires. This is done by multiplying the operating current by the number of hours per day your equipment will be required to operate.

3. Based on the zone the solar power system will be installed and the amp hour per day requirement, use the chart below to identify a corresponding "Output Capacity" letter.

4. Use the model number charts below to locate the correct "Output Capacity"
letter and select your model number.

Example:
(Equipment Current X 2) + 10% X (Equipment Run Time in Hours = Load-amp Hrs/day
(0.04 X 2 = 0.08) + 0.008 = 0.088 (Amps) x 24 (Hrs) = 2.1 Load-amp Hrs/day

Based on this example you would pick:
Letter "B1" for Zones 4 and 5, "B2" for Zones 2 or 3, and "B3" for Zone 1.

Load-amp Hrs/day 1.2 2.4 3.6
Zone 1 A3 B3 C3
Zone 2 A2 B2 C2
Zone 3 A2 B2 C2
Zone 4 A1 B1 C1
Zone 5 A1 B1 C1
General Specifications
Operating Temperature: -40 to 140 ºF (-40 to 60 ºC)
Enclosure: Fiberglass/Plastic Blend NEMA 4X
Minimum Battery Reserve Time: 5 days (120 hrs)
Regulated Output: 24 Vdc
Installation: Side of Pole, Roof or Wall Mounted
Estimated Battery Life: 4+ Years*

Available Models
Model Number SPSB-24VDC-10W-12 SPSB-24VDC-15W-12 SPSB-12VDC-20W-12
Output Capacity
(Letter Code)
A1 A2 A3
Solar Panel Watts 10 Watt, 18V 15 Watt, 18V 20 Watt, 18V
Charge Controller 6 A 6 A 6 A
Battery Capacity 12V, 12 Ah 12V, 12 Ah 12V, 12 Ah
Enclosure Size
inch (mm)
9.6 X 7.8 x 4.8"
(304 x 203 x 162mm)
9.6 X 7.8 x 4.8"
(304 x 203 x 162mm)
9.6 X 7.8 x 4.8"
(304 x 203 x 162mm)
Model Number SPSB-24VDC-15W-22 SPSB-24VDC-20W-22 SPSB-24VDC-30W-22
Output Capacity
(Letter Code)
B1 B2 B3
Solar Panel Watts 15 Watt, 18V 20 Watt, 18V 30 Watt, 18V
Charge Controller 6 A 6 A 6 A
Battery Capacity 12V, 22 Ah 12V, 22 Ah 12V, 22 Ah
Enclosure Size
inch (mm)
12 X 8 x 6.4"
(304 x 203 x 162mm)
12 X 8 x 6.4"
(304 x 203 x 162mm)
12 X 8 x 6.4"
(304 x 203 x 162mm)
Model Number SPSB-24VDC-20W-30 SPSB-24VDC-30W-30 SPSB-24VDC-40W-30
Output Capacity
(Letter Code)
C1 C2 C3
Solar Panel Capacity 20 Watt, 18V 30 Watt, 18V 40 Watt, 18V
Charge Controller 6 A 6 A 6 A
Battery Capacity 12V, 30 Ah 12V, 30 Ah 12V, 30 Ah
Enclosure Size
inch (mm)
12 X 8 x 6.4"
(304 x 203 x 162mm)
12 X 8 x 6.4"
(304 x 203 x 162mm)
12 X 8 x 6.4"
(304 x 203 x 162mm)
 * Battery life is dependent on system load, depth of charge cycle and ambient temperature.